PC Cooling

Custom Water Cooling: Soft Tubing, Radiators and Sizing

Choose soft tubing and fittings, size radiators with a rough wattage rule, and learn pump, coolant and leak-test basics for a custom PC water loop.

On this page
  1. How a custom loop differs from an AIO
  2. Soft tubing vs hard tubing
  3. Tubing sizes and fittings
  4. Sizing radiators
  5. Dual radiators: when a second one helps
  6. Pump, reservoir and loop order
  7. Coolant: what to use and what to avoid
  8. Leak testing before you power the full system
  9. Maintenance
  10. Common misconceptions
  11. Safety

A custom loop is a water-cooling system you build from separate parts instead of buying a sealed all-in-one (AIO) unit. It can cool a CPU and GPU together, and it gives you control over tubing, radiators and maintenance. It also takes more planning, and a leak in the wrong place can damage hardware. This guide covers the decisions that matter most: tubing, fittings, radiator sizing, the pump and coolant, and a leak test before you run the system.

How a custom loop differs from an AIO

An AIO is sealed at the factory, so there is one part to buy and nothing to plan. A custom loop asks more of you. You choose the pump, reservoir, water blocks, radiators, tubing and coolant. You also check for leaks, watch the coolant level, and change the coolant on a schedule. For the three cooler types side by side, see the PC cooling overview.

Soft tubing vs hard tubing

Soft tubing is flexible and easy to route, so it is the usual choice for a first loop. The two common soft materials are PVC and EPDM. PVC can leach plasticizer over time, which may leave a white residue in the loop. EPDM avoids that, but it is opaque.

Hard tubing is rigid and looks clean, but it takes more measuring, tools and skill to bend and fit. Common hard tubing materials include acrylic, PETG, glass and brass. PETG softens at temperatures roughly in the 60 to 80 °C range, so check a material’s rating against the temperatures your loop will see.

Soft tubing does not cool worse than hard tubing on its own. Choose the material by build style, skill and budget, and let the radiator, flow and fan speed drive the thermal results.

Tubing sizes and fittings

Soft tubing is sold by its inside diameter (ID) and outside diameter (OD). Common sizes include:

  • 10 mm ID and 13 mm OD (3/8” and 1/2”)
  • 10 mm ID and 16 mm OD (3/8” and 5/8”)
  • 13 mm ID and 19 mm OD (1/2” and 3/4”)

Compression fittings must match both the ID and the OD of your tubing. A fitting for the wrong size can leak. Most water blocks, radiators and reservoirs use G1/4” BSPP threads, so buy fittings with that thread.

Avoid sharp bends in soft tubing, because kinks restrict flow. Use rotary or 90-degree fittings where the tube has to turn tightly.

Sizing radiators

Radiator size is the biggest decision in a loop. A common rule of thumb is about 120 mm of radiator for every 100 W of heat you want to remove. A 250 W CPU and a 350 W GPU add up to about 600 W, which points to roughly two 360 mm radiators for quiet operation.

Treat that as a planning estimate. Radiator thickness, fin density and fan speed all change the result. A few guidelines help:

  • Thickness: thick radiators, roughly 45 to 60 mm, gain the most from higher fan speeds or push-pull setups. Slim radiators, around 30 mm, suit low fan speeds.
  • Fin density: lower fin density, around 10 to 13 FPI, suits quiet fans. Dense radiators need fans with higher static pressure.
  • Target temperature: a practical goal is coolant about 5 to 10 °C above room temperature under load.

Radiator wattage calculators work on the same idea. Use one to get a starting point, then check the result against your fans, case and noise limit, because a calculator can’t know those.

Dual radiators: when a second one helps

A second radiator adds surface area, so it can lower temperatures or let the fans run slower. The gains shrink as you add more radiator, so the benefit depends on your heat load. Two radiators help most when you have a high total heat load, want low fan speeds, or cool both the CPU and GPU in one loop. A single CPU rarely needs two. Two radiators also need room for both, so check the case’s mounting points and clearance before you buy.

Pump, reservoir and loop order

The pump drives the whole loop. D5 and DDC are the two common choices. DDC pumps are smaller and deliver higher head pressure, but they run hotter. Either can work when it is matched to the loop.

About 1 GPM (roughly 3.8 L/min) of flow is enough for most loops. More flow brings only small gains.

The reservoir should feed the pump inlet directly. Changing the order of the other parts usually moves temperatures by only about 1 to 2 °C, so don’t rebuild a loop chasing that.

Coolant: what to use and what to avoid

Use distilled water with a biocide and a corrosion inhibitor, or a premixed coolant made for PC loops. Never use tap water, because its minerals and microbes can clog the loop and corrode metals.

Match your metals too. Copper, brass and nickel can share a loop. Never mix aluminium with copper, because the pair can corrode through galvanic action. Opaque or pastel coolants often need servicing more often, so check the maker’s guidance before you choose one.

Leak testing before you power the full system

Test the loop before you trust it. Fill and bleed it, then run only the pump, using a PSU jumper so the pump starts without the rest of the system. Put paper towels under every fitting. Leave the loop running for 12 to 24 hours and check for drips and damp spots.

Never run the pump dry. Fill the loop before the pump starts. If anything leaks, power off and unplug before you touch the loop.

Maintenance

Check the coolant level regularly, because coolant can slowly evaporate and permeate through soft tubing. Plan a coolant change roughly every 6 to 12 months, and sooner if the coolant clouds or looks wrong. Clean the radiator fins and fan filters on the same routine you use for the rest of the case.

Common misconceptions

  • Loop order changes temperatures a lot. It usually moves them by a degree or two.
  • More radiator always gives big drops. The gains shrink as you add radiator.
  • Soft tubing always cools worse. Radiator size, flow and fan speed matter more than tubing material.
  • The wattage rule is exact. It is a planning estimate, not a measurement.

Safety

  • Never use tap water in the loop.
  • Never run the pump dry.
  • Keep the PC unplugged while you install or change loop parts.
  • Check every fitting after the leak test.

For a sealed alternative and the noise trade-offs that come with it, see AIO pump noise. Radiator fans can follow a curve too, so see how to set a fan curve.

The complete guide to pc cooling

Desktop PC Cooling Explained: Air, AIO and Custom Loops
Read the guide

Keep exploring

Guides from other topics

All topics →